Truma control panel fault codes 103. Looking for more information? Visit https://www. If you do anything it will invalidate the warranty on that piece of equipment and any subsequent damage caused by your attempts to fix it. : 0004 Flashing code: ssss slss Fault No. Initially we just used the panel manually. The temperature on the control panel is set lower than the actual temperature inside the motorhome. Does anyone know what the fault code E551H means on a Truma Combi D4E next generation I got a fault code W255H on the control panel, went to the book and it states fault or break in 230V! On Truma's website the same fault states 12v power interruption? After loads of checks on different cables/fuses coming from the Sargent EC400 no voltage showing on the yellow cable coming from the EC400 to the heater via a 3 pin connector. Aventa eco and Aventa comfort referred to as Aventa below. Remedy fault 507 / 516 / 517 (gas supply interrupted) Restore the gas supply, for example by connecting a full gas cylinder. So I was having plain sailing just going from aire to aire not hooking up as I was running of Note: If the fault 507, 516 or 517 is displayed in the heater's control panel, switching the control panel on and off does not help. Thank you. Truma Combi referred to as Combi below. I then downloaded the Truma app to my android phone and connected via bluetooth. 5. 5 seconds . RV Parts Department Combi E in mixed mode (combined gas and electric heating operation): Warning indicates lack of gas supply. For More Information, you can contact or visit Truma Combi D 6 Online-Anleitung: Trouble-Shooting List. ” On outside of the RV, turn the AquaGo toggle switch to the “off ” position. Other connected appliances can be operated. 9. The fault code 507, 516 or 517 flashes because the heater is still in a 15-minute blocking time. co. fault code w255h which id no 12v power to truma heater! Now I'm stumped? Error code e507h on my motor home. Why not? And how do you get rid of it? These mover models have the flashing code output: Mover XT models; Mover SX; Mover SER/TER; Mover SR; l. Trouble-shooting list Flash code on the control panel Flash sequence LED: – On: 0. reading time 2 minutes. for air conditioning systems and Truma E-Kit. com Failing that maybe Action: Replace circulating air motor Fault No. I have a Truma Combi D 6 heater with a problem. We love our caravans but they are fragile. I switched the panel "Off" hoping the restart would solve the problem but unfortunately I now cannot restart the panel - this leaves me with no heating and no hot water. To fix this issue, we ask you to install panel release with version 2. Llyn Peninsula Funster No it can possibly be due to 12v interuption befroe you shut down the Control panel. uk I hope this helps, but basically, patience and a reset Page 1 Truma CP plus Digital Control Panel If the information in these instructions is not followed exactly, a fire or explosion may result, Operating instructions Page 2 Installation instructions causing property damage, personal injury, or Page 14 death. Service integrated: instructions rather than cryptic fault codes; Always up to date with extensions and updates; Sophisticated menu guidance and user interface. Action: Replace heating element The power supply to the heater may have been interrupted by switching off the vehicle control panel (not the Truma heater control panel). Make connection between heater and control panel Control panel cable faulty Contact Truma Service If these measures do not remedy the fault or if fault codes are displayed that you cannot find in the troubleshoot- ing guide, contact Truma Service. Fault code was 45 tried pressing the reset button and checked the t10ah fuse located under the flip up panel on the boiler but both were ok. Download Truma Combi CP Plus PDF manual. 12v and 240 connected the temp sensor and control panel 12v. Check power supply, AC components also possible through power supply units or solar systems. com. Once the flush cycle is complete, the green LED above the toggle switch on the outside of the AquaGo will go off. Tried reset on the panel and it rebooted Looked at the truma control panel that had the normal display and thought resetting might cure the fault. Products Rather than cryptic fault codes in the event of malfunctions, specific instructions with details on the possible cause make it easier to The Truma iNet X Panel is the central control panel of the iNet X System for retrofitting. I have read here about resetting the microswitch but there doesn’t seem to Help with Truma fault code E5 15H. If you can get to your boiler and do a hard reset by pressing (if you have one) the brown button near where the wires enter This is a basic video on how to re-set the Truma combi boiler after a GAS lockout. the C-heater. Ensure 12 V power is at the Combi. The digital control panel CP plus 2022 Winnebago Travato 59KL 2017. 2019 Flashing code: sssl ssll Fault description: Electronics do not match the heater (e. Company The Truma cp control panel on my 2016 Sterling Eccles has lost the electrical heating symbol on the fuel source options, ie gas, mix, electric 1 &2. Naturally it’s waited till it’s out of warranty. Get exciting product updates and useful caravaning news! Sign-up. Page 14 To be kept in the vehicle. Truma iNet X Control Panel Product Ref: 281181 Truma Code : 36411-51 £ 246. Many thanks. fault W621 H "temp sensor error" it shows a picture of a plug on the bottom RH the book says Mains available. On your control panel you then switch to pure gas mode of your heating system – the warning [] There are two LEDs on the back of the panel that indicate the operating status of the control unit as soon as 12V are applied Read more The Dometic Freshjet FJX is recognized by the iNet X (Pro) panel, but it does not cool. Truma is a reputable manufacturer of various comfort systems designed for mobile living, particularly in the camping and Motorhome industry. If none of the measures in the troubleshooting chart proves successful or fault codes are displayed that cannot be found in the troubleshooting chart, please contact the Truma Service Center at 1-855-558-7862 or one of our authorized Get exciting product updates and useful caravaning news! Sign-up. Truma Combi D referred to as Combi D below. ” Turn the toggle switch on the AquaGo to the “Off” position. This was possibly caused by the heater control panel being switched off or because the You see the warning message “W255H” on your digital display and cannot control your heating anymore? This primarily indicates a connection problem between the digital control panel and the heating. Is the W255H flashing and if it is then wait 20 minutes and then try a reset. With the Combi Gas connected to the CP classic analogue control unit, the flashing code also provides more precise information on the cause of the fault. 641-585-3213 www. For technical reasons they are referred to as “HEATING” in the display text. It also corresponds perfectly to the LED sequence that is flashing on the unit itself. Social groups Having followed a number of these 517 fault code posts it often turns out to be the regulator failing to supply enough gas I have a problem with my mileo 346 Truma control panel as its not showing any of the normal icons ie top row of icons it just shows the clock icon & a spanner icon. They are on page 13 of the Truma manual – – or, right here. Pause between flash sequence: 5 This document provides fault codes and descriptions for diagnosing issues with Truma Combi heaters. you’re describing with your Truma D4E Combi heater showing a green light that flashes three times suggests a Step 02 – Make The Recirculation Pump Click. Page 2: Table Of Contents Truma told me we have a combustion air motor problem: it's either the motor, its wiring harnass, the control board or all of Truma combi died - Forest River Forums Journey with Confidence RV GPS App RV Trip Planner RV LIFE Campground Reviews RV Maintenance Take a Speed Test Free 7 Day Trial × Truma boiler problem Hi - The flashing led is as you say giving a fault code made up of dots & dashes (quick & long flashes). The Combi heaters were launched by Truma in 2007 and can be Truma Cp Plus Online-Anleitung: Troubleshooting Guide For Combi Gas Heater (H). The controller indicates no fuel by flashing red six times. The Auto-Sleeper Motorhome Owners Forum (ASOF) I would like to have a go myself. The Truma CP Plus is a digital control panel used in conjunction with Truma heating and air conditioning systems for Motorhomes and caravans. Away at moment and above code has come up on control panel, so no heating or hot water (do have a separate heater though). Thank you, ***** read more Combi D 6 la primera generacion Combi D 6 la siguiente generación angular wankamin redondo wankamin número de serie CBD06EU-E-xxxxxxxx o CD600-xxxxxxxx número de serie The Truma control panel also showed E517H What's New Home. Henrik Børresen on W255H in digital control panel or the control panel. after an power failure. What should I do? A: Flashing Code E-514-H displayed in the Truma control panel is due to an incorrect shut down of the electrical system. 20. See Also Gas Water Heater Leaking and No Hot Water: Causes and Solutions to Restore Your Comfort Winter is well and truly here so make sure you prepare your Truma Combi boiler by draining down your tank: ️Open the drain valve with the yellow handle (manual drain valve) or turn the blue switch Operating instructions Page 2 . Please take care of them as you would your own. I told them my code & they came back with an answer that was Switched back on no display on panel apart from time and timer? Switched off again and disconnected power and battery. Combi 4/6 (E) With the Combi Gas connected to the CP classic analogue control unit, the flashing code also provides 117 Dirty supply voltage AC components in power supply. Your Truma heating and hot water system. Gas full, 12v power full. Fault Figure 28 In the event of a fault, the Truma CP plus VarioHeat control Icon appears only in conjunction with a Truma air con- panel immediately jumps to the “Fault” menu level and dis- TRUMA iNet Panel - X Panel Error code 503 The fault code 507, 516 or 517 flashes because the heater is still in a 15-minute blocking time. If the laid TIN cables exceed an overall length of 12 metres, this can lead to a fault in communication with the digital control panel (W255H). motorhomefun. Change cabel between Combi and control panel. If this connection is interrupted, the control panel responds with the message W255H. 5 Winnebago Travato 59K 2008 Sportsmobile Sprinter Hi I have a fault with my caravan Truma 6 uk version combi boiler, the fault code is E6H,can you please tell me how I can reset it. If none of the measures in the troubleshooting chart proves successful or fault codes are displayed that cannot be found in the troubleshooting chart, please contact the Truma Service Center at : Help! The truma control panel has thrown a wobbler. Truma can tell what's wrong from this code. The digital control panel CP plus Customer service contact, operating instructions, FAQs, guarantees, camping guide, fault codes, troubleshooting, workshop service and much more. Skip to content. Control panel cable defective. Remedy fault 507 / 516 / 517 (gas supply interrupted) Then confirm or delete the fault code by tapping the rotary push button. Flash sequence LED: – On / Off: 0. In this state, View and Download Truma CP plus operating instructions manual online. Tried to reset on the panel but now it wont reconnect to the boiler. I removed the 12v fuse on the panel and tested - OK. Forum list. control panel. Then confirm or delete the fault code by tapping the rotary push button. XXX. See to the TRUMA CP CLASSIC GAS MODEL error codes: Flashing code at analogue control panel – CP Classic. That code usually means that there is no 120v power coming to the Truma while you are trying to use one of the electric modes for room heat or hot water. Our Refillable gas low ones have gauges. New items New reviews Latest content Latest reviews Latest questions Latest check-ins. When selected the code read W255 W. 1. I am a little doubtful Tried power off, reset on Truma display No code on the Truma site Found this but doesn’t work: A: Flashing Code E-514-H displayed in the Truma control panel is due to an incorrect shut down of the electrical system. If the Truma iNet X is switched off, all connected heating The control panel is operated with your fingers via the and air conditioning systems are also switched off. The heater is also blocked for 15 minutes if the fault 507, 516 or 517 is deleted four times without the gas supply being established. An error code is shown on the display of my digital CP plus control panel – how do I find out what it means? Detailed information about the fault codes, their cause and how to fix them can be found in the Operating and Installation Instructions of the Truma CP plus. The heating system now requires turning off at Truma control before powering down the van or turning the main 12v master switch off. Find the answer to this and other Home Improvement questions on JustAnswer the control panel. This update is available via the Truma iNet X App, starting from v 1. 2019 Fault No. Customer service contact, operating instructions, FAQs, guarantees, camping guide, fault codes, troubleshooting, workshop service and much more. Please note that the first tap might only activate the backlighting of the control panel. Even updating the firmware via bluetooth. The power supply to the heater may have been interrupted by switching off the vehicle control panel (not the Truma heater control panel). 5 Gabor explains how to fix a W 255 H fault code on your truma boiler. Rallies. 24 “Warning / Error” menu level and displays the respective fault code. These instructions apply to the Truma CP plus control panel, referred to a CP plus below 1. Forums. Company The Truma CP plus is a digital control panel for use with the Truma AquaGo, Truma Aventa, Truma Combi, and Truma VarioHeat. net/support or contact our Customer Care Well just wired up my new Truma 4e. 125 Found this but doesn’t work: A: Flashing Code E-514-H displayed in the Truma control panel is due to an incorrect shut www. Action: Check / replace combustion air motor Diagnostics catalogue Truma Combi Page 2 / 57 04. The heating system now requires turning off at Truma control before powering down the van or turning the main 12v master The Truma iNet X Panel is the central control panel of the iNet X System for retrofitting. Alternatively try lighting the hob. g. The Top Winnebago Dealer in North America! 1-641-585-3213. The heating then starts automatically if there is a heating requirement. Preparing the 12 V DC electrical Mounting the control panel Only AquaGo® comfort / connection AquaGo® comfort plus All electrical connections must be made in compliance with all national, regional or lo- • Damage to the control panel cal electrical codes. Re-connected, no display again not showing 240v plug on display? Disconnected 240v tried to run off 12v as battery full. Feb 18, 2018. Page 16: Maintenance What should I do if the control panel displays a warning or error? The 8th part of our video series for operating the Truma CP plus shows you what to do in t This is fault code 31 “Decalcification Complete”. I have recently experienced an issue with the Truma CP Plus control panel having lost all functions which transpires that the rotating knob had, over a per. Fault No. Included in delivery: LCD-Display Truma CP plus including a 12 V connection and a 6 m control panel cable For the retrofitting of vehicles with older Combi systems (grey case) the CP plus control panel has to be mount and the control unit PCB of the heater has to be With the Combi Gas connected to the CP classic analogue control unit, the flashing code also provides more precise information on the cause of the fault. In this video, we explain how to use the Truma Combi Control Panel. The “Control panel cable coupling” accessory is the Ensure connection between furnace and control panel. Setting uo at campsite once shorepower was connected the Truma Control Panel showed Alert diamond in center at bottom control panel. Thread starter Captain Lloyd; Start date Feb 17, 2021; Captain Lloyd. I have a few problems/ questions, probably my fault. Combi D 6 (E) 1 Control panel, digital or analogue (no picture) 2 Room temperature sensor 3 Cold water connection 4 Hot water connection 5 Fuel line connection 6 Warm air outlets 7 Circulated air intake 8 Exhaust gas discharge 9 Combustion air infeed 10 Electronic control unit 11 Water container (10 litres) and Truma CP classic (control I have a 2014 Lunar Quasar. lichtsinn. If you try and clear it before 15 minutes has elapsed, either from the appearance of the fault, or after switching the system off and on again, it won't allow the fault to be cleared. How do you clear a Truma fault code? Leave the heater for 15 minutes. When I try to Fault no. Warm-air outlet blocked. You will see a red LED light fault code below the toggle switch. I have the gas symbol but it just jumps over where the double electric should be Remote control Truma CP plus. 99 (inc Rather than cryptic fault codes in the event of malfunctions, specific The Truma system keep dishing out the warning codes (which are not in the book and are not on-line - of course they have not emailed back). Page 1 Truma Combi Service Handbook; Page 2 *** Please include the model and serial number of the Truma system in question with all inquiries. Check Fault Cause Rectification; No LED is on, the unit is switched on and is supplied with operating current – Automatic restart is blocked, e. It shouldn’t take more than 20 minutes to do it. This document is part of the product. I was now shown a clock and a spanner! It then gave the fault code W255H. The manuals provided on flashdrive to = VarioHeat = AquaGo Fig. Fault Code Cause W 17 H Summer Mode With Empty Water Container W 18 H Warm Air Temperature Exceeded: Not All Warm Air Ducts Are Connected If you cannot get rid of an error code on the iNet you can sometimes fix it by doing a hard reset of the control panel. This was possibly caused by the heater control panel being switched off or because the heater’s 12-Volt supply was interrupted. Calor gas bottles will be light when you pick them up. Sure it’s been raised before but can anyone please tell what it denotes. Combi E in mixed mode (combined gas and electric heating operation): Warning indicates lack of gas supply. Contact Truma Service. which means the furnace is malfunctioning. Page 19: Troubleshooting Guide (Combi Diesel Heating System) Fault No. The fault was the lower fuse only accessible by removing the side panel held in place by two tork head screws top left and top right then folding panel forward and pressing down to unclip from boiler. The heating system now requires turning off at Truma control before powering down the van or turning the main 12v master switch off. Turn on all the hot water faucets to drain the water. The LCD display control panel CP Plus can always be retrofitted in all Truma Combi heaters. As soon as a fault is indicated on the remote control, the LED (j) on the control unit emits the flashing code. . Thread starter Lynne Roy; Start date Oct 16, 2021; Lynne Roy. Switch off Combi and allow to cool. The control panel currently allows appliances and switches from various manufacturers to be controlled, and also displays status queries, additional functions will be made available in future. After about 15 mins of flashing, it allows me to turn everything back on again and its business as usual Learn how to operate your Truma AquaGo using the Control Panel. A heating fault appeared in the truma combo control panel. The panel is therefore the key to our new technology that makes your vehicle smart. This can occur when the GAS bottle are switched off and you have selected We recently bought a camper van with a Truma 6DE heater, Truma CP control panel and Truma Inet box. The “Control panel cable coupling” accessory is the Note: If the fault 507, 516 or 517 is displayed in the heater’s control panel, switching the control panel on and off does not help. If the control unit reports a malfunction, the cause can be narrowed down more precisely using the flashing code on the heating board. These mover models have the flashing code output: Mover XT models; Mover SX; Mover SER/TER; Mover SR; l. After about 15 mins of flashing, it allows me to turn everything back on again and its business as usual In this video we will show you how to fix the following error codes 507,516 & 517 on the Truma heating system . Truma CP plus control panel pdf manual download. 09. All this was seemless and worked without flaws. It cannot be fitted into older heater models, e. Ensure connection between furnace and con Control panel cable defective. A: Flashing Code E-514-H displayed in the Truma control panel is due to an incorrect shut down of the electrical system. The control panel is used to control How to rectify warning code W255 on your CP+ panel which could be one of three things that you can fix on the spot. When installed as an original component by an RV manufacturer, the Aventa may be additionally controlled by the Truma CP plus control panel or integrated into a third-party – The temperature setting on the control panel is lower than the room temperature – Select higher room temperature at the control panel 🎥 : Green LED flashes (with 5 Hz) after the heating system has been switched off – After-running is active to reduce the temperature of the unit – No fault, after-run switches itself off after max. : 0028 Flashing code: sssl llss Fault description: Control panel or control panel cable defective 1. : Flash code s = short l = long Fault Fault description 46 s,s,l,s l,l,l,s – control panel Combi or energy selector switch Combi E defective – combustion air motor or hot-air motor defective – battery earth to the minus terminal Combi defective – control panel or control panel cable defective – energy selector switch Combi E The Truma iNet X Pro Panel is the central control panel of the iNet X System and therefore the key for setting up new vehicles to use this new technology. 2)Control panel cabel faulty or damaged. Combi and Combi D are furnaces. Page 31: Connection Diagrams Buy a Truma Combi Flame Tube Truma Code: 34020-60900 Truma Combi heaters Spare Parts Leisureshopdirect Tried the boiler fuse in the main panel - OK, so had to remove the electric panel on the side of the heater unit (not an easy job, it's buried under the seating and kitchen units). : 0255 Flashing code: llll llll Fault description: - No connection between heater and control panel - Heater has no 12 V power supply - Control panel cable faulty Truma Combi CP Plus Quick Start Manual View and Read online. The heater is also blocked for 15 minutes if fault 507, 516 or 517 is deleted four times without the gas supply being established. There are two LEDs on the back of the panel that indicate the operating status of the control unit as soon as 12V are applied Read More The Dometic Freshjet FJX is recognized by the iNet X (Pro) panel, but it does not cool. 1,201 2,430. Installation instructionscausing property damage, personal injury, or . On your control panel you then switch to pure gas mode of your heating system – the warning [] The fault code relates to an electrical fault typically an over current condition, often seen where there is an intermittent issue on the heating element, and noticeable as the fault occurs only when using the heating element (and not gas). Ive been looking high and low for that information. Action: Replace heating element Diagnostics catalogue Truma Combi Page 1 / 57 10. immediately jumps to the “Malfunction” menu level and dis- plays the fault code of the fault. Why not? And how do you get rid of it? The fault code 507, 516 or 517 flashes because the heater is still in a 15-minute blocking time. The Green Led Comes On When The Models where it applies: Nomad / Nomad Ivy How to identify if your heater works with Diesel or gas? These models (Nomad and Nomad Ivy) Truma CP plus control panel referred to as CP plus below. Hi all. 4 Target group These instructions are intended for users To make the text easier to read, no gender-specific The fault W407H means that the mains voltage is too low or missing. Please check that the window in question is locked when completely closed. I tried to follow the instruction to remedy this but unsuccessful. Fault code E632 h is not listed. Action: Replace control panel Fault No. If none of the measures in the troubleshooting chart proves successful or fault codes are displayed that cannot be found in the troubleshooting chart, please contact the Truma Service Center at : The TIN cable is used to transmit commands from the control panel to the heater. Page 6: Resetting Faults Bluetooth Low Energy (BLE) Power supply Truma iNet X. Digital control panel for the Truma AquaGo, Truma Aventa, Truma Combi, and Truma VarioHeat with automatic climate control, boost function, and time switch. Solutions to rectify the fault are suggested in 8 V – 16 V Power consumption the display. Henrik Børresen on W255H in digital control panel or Remote control Truma CP plus. www. Detailed information about the fault codes, their cause and 2023 Elite II with Truma A/C, Truma on-demand hot water heater and Furnace, Isotherm frig. Turn the analog dial to “Off. This could happen if you are not connected to a mains power supply or if there is a problem with the wiring or the fuse. Combi D 6 först generationen Combi D 6 nästa generationen fyrkantig vägg öppen spis rund vägg öppen spis seriennummer CBD06EU-E-xxxxxxxx eller CD600-xxxxxxxx seriennummer CBD06EU-F-xxxxxxxx Combi Note: If the fault 507, 516 or 517 is displayed in the heater's control panel, switching the control panel on and off does not help. : 0005 Flashing code: ssss slsl Action: Replace control panel Fault No. Please check whether the plug of the TIN cable is correctly seated in the socket on both the control element and the control board of the heater. Toggle navigation Menu Contact Us Contact RV Search Search Home; New RVs; Used RVs; Parts & Service. When the cover was removed there was a red LED flashing a code of short and long bursts - clearly a fault code. Press the rotary push button for long enough for the control panel to power and leave it for 20 minutes before trying again. Search for: Helpful Documents The Truma CP Plus is a digital control panel used in conjunction with Truma heating and air conditioning systems for Motorhomes and caravans. The vehicle has half a tank of fuel and is on level ground. Second question, could anyone recommend a Q: I have a flashing fault code E-514-H showing on my Truma control panel. The fault code E622H points towards either the room temperature sensor or wire. Please note that the first tap might only activate the backlighting Get exciting product updates and useful caravaning news! Sign-up. 02. Restore the gas supply for example by connecting a new gas cylinder. Sep 19, 2016. : 0029 Flashing code: sssl llsl Fault description: FrostControl heating element current too high 1. The heater now only runs in electric mode. 26 Malfunction In the event of an error, the Truma CP plus Var- ioHeat control panel immediately jumps to the Fig. 3 Product names Aventa eco and Aventa comfort are referred to as Aventa below Truma iNet Box is referred to as iNet Box below 1. The new air conditioning control function controls the system via the Truma App. Flash Code On The Control Panel Flash Sequence Led: – On: – Off: Pause Between The Flashing Sequence: 3 Seconds Fault After Switching On (Winter And Summer Opera- Tion) None Of The Leds Are Lit. These mover models have the flashing code output: With the Combi Gas connected to the CP classic analogue There are a few reasons why your Truma hot water and heater system could display a triangle with an exclamation mark and an error code. After many many attempts to re set from the Truma Control panel I also tried to reset from the reset button on the Truma unit itself but had no luck. Phoned Truma who, as soon as I said no lights on the PCB, that the board was broken! Greetings campers! I have a 2017 Basecamp 16 and am seeking help! I'm experiencing a Truma error code E212-H. To be kept in the vehicle. If the Truma Service Representative is unable to support in finding a resolution to the issue, they will provide you a Warranty Claim Number if the unit is within the Warranty Claim period and the following steps must be Prepare to read! This article is the one stop shop for all things Truma. Combi CP Plus Control Panel manuals and instructions online. Gas hobs working but not fridge or heating Truma Combi. View and Download Truma Combi D 6 operating instructions manual online. Th wow, thanks. Something of an annoyance this, so hopefully someone can help! When firing up the heating / hot water via the Truma control panel, i'm getting this flashing E514H message on the screen. 1) Combi has no connection to 12 V power supply. This is fault code 31 (S,S,S, L,L,L,L,L) “Decalcification Complete. Company 2018 (2017 Sprinter Cab Chassis) Navion24V + 2016 JKU (sold @ ????) 2016 Sunstar 26HE, V10, 3V, 6 Speed (sold @ 4600 miles) 2002 Roadtrek C190P (sold @ 315,000kms) Detailed information about the fault codes, their cause and how to fix them can be found in the Operating and Installation Instructions of the Truma CP Read more Page 1 Page 2 Page 3 Page 4 Page 5 Your heater includes a window switch which prevents the heater from starting up if the side window above or right next to wall cowl of your heater is not completely closed. Pilote 396 evidence 2023. Combi D 6 heater pdf manual download. It lists 57 fault codes ranging from 0004 to 0046 with corresponding flashing codes, fault descriptions, and recommended TRUMA CP PLUS GAS MODEL error codes: Hot water mode with empty water container. This does not delete the fault but blocks the heater for 15 minutes. Thank you to TheBows for putting your original post on The two timeout errors mentioned are missing information from the fresh and grey water sensors. Diagnostics catalogue Truma Combi Page 1 / 57 10. How to Reset Truma Error Code E517H | Causes & Reset ProcedureIn this, the fourth in a series of "How To" videos we show a possible cause of the Truma error Truma fault codes. but no small electric sign on the Question - I have a truma combi e with fault code W255h, yes tgere is - . from wetness and moisture. 5 seconds – Off: 0. Call 0220 694828 if you need help. Depends what system you have. I have a problem in my Truma 6E heater in my 2019 Chausson 727 GA. Est. Combi 4/6 (E) With the Combi Gas connected to the CP classic analogue control unit, the flashing code also provides more precise information on the cause of the fault. 5 seconds Pause between the flashing sequence: 3 seconds Fault Cause Rectification After switching on – No operating voltage Note: If fault 507, 516 or 517 is displayed in the heater's control panel, switching the control panel on and off does not help. Fill water container with water. I then found that to actually re-set the Heater properly you have to hold in the re-set button for 3-5 seconds maybe more maybe less I can't quite remember, until the green light flashes. LIFE MEMBER. There is therefore delayed communication between the panel and the EBL. Clearing codes To clear the above fault codes carry out the remedy as necessary and the boiler in most cases with rectify itself. New events. Truma VarioHeat (H) Fault code Cause Remedy E 2 H Flame not recognised: E 16 H – Gas cylinder empty – Replace gas cylinder – Gas cylinder or quick Page 1 Truma iNet Panel / Truma iNet X Panel EN Operating instructions Page To be kept in the vehicle; Page 2: Table Of Contents Truma iNet Panel / Truma iNet X Panel Table of Contents 5 6 App control (Bluetooth) 10 Faults 11 About these instructions 3 Software update 12 1 1 Document number 3 1 2 Validity 3 Replacing the battery 12 1 3 When the operating parame- ter is within the target range again, this symbol goes off again In the event of a malfunction, the Truma CP plus control panel automatically. Nothing working g and no error code. The operating parameters are shown on the status control panel, Truma VarioHeat and Truma E-Kit and 230 V bar (2) and on the displays (5, 6). Please work through this troubleshooting list to eliminate and solve the fault. You'll find reference, troubleshooting, and warranty guidelines for the Truma systems: Control panel, Truma AquaGo Comfort Plus (water heater) and Truma Varioheat (furnace) Some codes require the system to be left on with the code present on the control panel for 15 minutes before you can reset them, as they cause the system to lock-out. Action: Check / replace control panel cable 2. Remote control Truma CP plus. The replaced Truma control panel rotating knob had been pushed in too far, would you believe, but is now working on both gas and electric, thank goodness. Reviews. truma. Then when the flashing warning triangle has gone solid, scroll to it and confirm or delete the fault code by tapping the rotary push button. Skip to main content. 6 kW PCB in 4 Digital control panel for existing Truma Combi devices produced from 2007 on. Arrived on campsite today, turned heating on, no heat or hot water but code W255 H . The reason for this is the 12V supply to the Truma Control Panel has been interrupted. As the van is still within warranty it is a job for the supplying dealer to sort out. Now Here you can find operating instructions and more for our Truma products to download free of charge From time to time you may experience the W255 H error code on your Turma Unit, this should help with a quick and easy way to hopefully clear that code error The heater does not have 12 Volt power supply or there is no connection between the heater and the CP plus control panel. The Truma iNet X Panel is the central control panel of the iNet X System for retrofitting. : 0005 Flashing code: ssss slsl Fault description: Combustion air motor current too low 1. This does not delete the fault, but blocks the heater for 15 minutes. Reset and when init (alising) found the panel could not see the boiler. njcuy xhmye kjqwf emyv uvhuuac axuazn uvqq ysguj cvnmty lonb